DSH 285
Subject: Live Loudspeaker Terminals
Question:
a) Are live loudspeaker terminals allowed to be accessible?
b) Is the Provision of a cover to be user-installed over the live speaker terminals after connection of speaker wiring an acceptable method of making the terminals inaccessible?
c) Is a cover installed over speaker terminals to make them inaccessible, allowed to be removable by hand?
Decision:
a) No.
Live loudspeaker terminals shall not be accessible.
b) Yes.
Provision of a cover to be user-installed over the live speaker terminals after connection of speaker wiring is an acceptable method of making the terminals inaccessible.
In addition there shall be the appropriate information in the users manual
c) No.
If a cover is installed over speaker terminals to make them inaccessible, it shall not be removable by hand.
問題:
a)是否允許接觸帶電的揚聲器端子?
b)是否接受在揚聲器端子連接完畢后再由用戶安裝蓋子來避免接觸端子的方法?
c)用于避免接觸揚聲器端子的蓋子,是否允許徒手拆卸?
決定:
a)不行,帶電的揚聲器端子不應被接觸。
b)可以,在揚聲器端子上安裝蓋子避免接觸是一種可行的方法。同時在用戶手冊中應有相關說明信息。
c)不行,避免接觸揚聲器端子的蓋子不應被徒手拆卸。
************************************
DSH 286
Subject: Mains Switch Location
Question:
Is it allowed to have the mains switch on the rear of a floor standing powered speaker?
Decision:
Yes.
The mains switch may be on the rear of a floor standing powered speaker.
Rationale: The user may walk behind the speaker to access the rear panel.
問題:
是否接受落地式揚聲器的電源開關位于其后背部?
決定:
可以。用戶可以走到揚聲器背面去接近后面板。
************************************
DSH 287
Subject: Mains Cords for Double Insulated Apparatus
Question:
May Double Insulated Apparatus marked with the double square symbol be provided with a mains cord or inlet connector incorporating an Earthing Conductor?
Decision:
No.
Double Insulated Apparatus marked with the double square symbol shall not be provide with a mains cord or inlet connector incorporating an Earthing Conductor.
問題:
帶有“回”字標的雙重絕緣設備是否能夠含有接地線的連接器或電源線?
決定:
不行。帶有“回”字標的雙重絕緣設備不應含有接地線的連接器或電源線。